Allows the user to choose linearized relative permeability. The linearized relative permeability is formed using the nonlinear value of relative permeability at the iteration number IEXRLP. After that iteration a relative permeability value based on a Taylor series expansion in saturation is used.
- Group 1 - IEXRLP
Input Variable | Format | Description |
---|---|---|
IEXRLP | integer | If IEXRLP ≥ 1, then linearized relative permeability. Otherwise not enabled. |
In the following example of exrl
, the user enables linearized relative permeability at the first iteration.
exrl1 |
1 |