impf
¶
Time step control based on maximum allowed variable change.
- Group 1 - DELPT, DELTT, DELST, DELAT
Input Variable | Format | Description |
---|---|---|
DELPT | real | Maximum allowable pressure change for which time step will be increased. (MPa) |
DELTT | real | Maximum allowable temperature change for which time step will be increased. (oC) |
DELST | real | Maximum allowable saturation change for which time step will be increased. |
DELAT | real | Maximum allowable air pressure change for which time step will be increased. (MPa) |
The following is an examples of impf
. In this example, pressure changes are
limited to 0.5 MPa, temperature changes to 20 oC, saturation changes to 0.1, and
air pressure changes to 0.05 MPa during a time step.
impf | |||
0.5 | 20.0 | 0.1 | 0.05 |
© Copyright 2018, Los Alamos National Laboratory