impf

    Time step control based on maximum allowed variable change.

    • Group 1 - DELPT, DELTT, DELST, DELAT
    Input Variable Format Description
    DELPT real Maximum allowable pressure change for which time step will be increased. (MPa)
    DELTT real Maximum allowable temperature change for which time step will be increased. (oC)
    DELST real Maximum allowable saturation change for which time step will be increased.
    DELAT real Maximum allowable air pressure change for which time step will be increased. (MPa)

    The following is an examples of impf. In this example, pressure changes are limited to 0.5 MPa, temperature changes to 20 oC, saturation changes to 0.1, and air pressure changes to 0.05 MPa during a time step.

    impf      
    0.5 20.0 0.1 0.05

    © Copyright 2018, Los Alamos National Laboratory