szna or napl

    • Group 1 - ICO2D
    • Group 2 - TREF, PREF
    • Group 3 - DENNAPL, VISCNAPL
    Input Variable Format Description
    ICO2D integer Determines the type of air module used. ICO2D = 1, 1 degree of freedom solution to the saturated-unsaturated problem is produced. This formulation is similar to the RIchard’s Equation.
        ICO2D = 2, 1 degree of freedom solution is obtained assuming only gas flow with no liquid present.ICO2D = 3, full 2 degree of freedom solution.All other values are ignored. The default is 3.
    TREF real Reference temperature for properties (oC).
    PREF real Reference pressure for properties (MPa).
    DENNAPL real NAPL density (kg/m3).
    VISCNAPL real NAPL viscosity (Pa s).

    © Copyright 2018, Los Alamos National Laboratory