boun
Test the Boundry Functionality
Compares the generated contour files to old contour files that are known to be correct. Comparison of boun test results (flow macro vs boun macro). Only the pressure and hydraulic head values at time 2 are tested.
See compare files:
prob_well_boun1.00002_sca_node.avs
prob_well_boun2.00002_sca_node.avs
prob_well_boun3.00002_sca_node.avs
Test Directory: FEHM/fehmpytests/boun
Example File prob_well_boun1.dat
***Compare wellbore module***
cont
avs 1.e6 50.
xyz
geom
pres
head
liquid
formatted
endavs
head 0.
zone
50
all
#wtsi -1
#1 50 0.01 0.00000 1. -999. 0.0001
air
-2
20. 0.1
pres
1 0 0 250. 20. 1
time
1.e-3 1000 20 1 2007 10000 0.00000
iter
1.e-06 1.e-06 1.e-2 -1.e-3 1.15
13 0 0 5 1200.
perm
1 0 0 -13 -13 -13
rock
1 0 0 2650. 750. 0.15
cond
1 0 0 1 1 1
zonn
11
-0.1 0.1 0.1 -0.1 -0.1 0.1 0.1 -0.1
-0.1 -0.1 1000.1 1000.1 -0.1 -0.1 1000.1 1000.1
-0.1 -0.1 -0.1 -0.1 30.1 30.1 30.1 30.1
12
999.9 1000.1 1000.1 999.9 999.9 1000.1 1000.1 999.9
-0.1 -0.1 1000.1 1000.1 -0.1 -0.1 1000.1 1000.1
-0.1 -0.1 -0.1 -0.1 30.1 30.1 30.1 30.1
13
-0.1 1000.1 1000.1 -0.1 -0.1 1000.1 1000.1 -0.1
-0.1 -0.1 0.1 0.1 -0.1 -0.1 0.1 0.1
-0.1 -0.1 -0.1 -0.1 30.1 30.1 30.1 30.1
14
-0.1 1000.1 1000.1 -0.1 -0.1 1000.1 1000.1 -0.1
999.9 999.9 1000.1 1000.1 999.9 999.9 1000.1 1000.1
-0.1 -0.1 -0.1 -0.1 30.1 30.1 30.1 30.1
21
list
300. 500. 100.
boun
model
ti
2 0. 1.e20
dsw
-10. -10.
-21 0 0 1
flow
-12 0 0 200 1. 1.e-4
-13 0 0 200 1. 1.e-4
-14 0 0 200 1. 1.e-4
-11 0 0 200 1. 1.e-4
#boun
#model
#ti
#2 0. 1.e20
#hd
#200. 200.
#
#-11 0 0 1
#
node
block
-21 0 0
-11 0 0
hist
years 1 1.e20
mpa
deg
end
ctrl
-20 1.e-06 40 100 gmre
1 0 0 2
1.0 3 1.0
20 1.500 1.0e-7 100.
0 0
stop
fdm
poin
21 21 16
1 0.0
-21 1000.
1 0.0
-21 1000.
1 200.
-16 0.