rad_decay

    Test radioactive decay option in rxn macro

    The simulation is a batch reactor without flow and comparison is made to the Bateman equation. Decay of 135I->135Xe->135Cs is modeled. The test ensures that FEHM matches the bateman equation within 10% relative error for all concentrations greater than 1e-6 moles/kg vapor.

    H. Bateman. “Solution of a System of Differential Equations Occurring in the Theory of Radio-active Transformations,” Proc. Cambridge Phil. Soc. IS, 423 (1910) https://archive.org/details/cbarchive_122715_solutionofasystemofdifferentia1843

    This test case is not party of the VV Test Suite and does not use files in /compare as reference, instead the results are compared against equation values in bateman.py

    Test Directory: FEHM/fehmpytests/rad_decay