ramey
Test Temperature in a Wellbore Problem
Compares the generated contour and history files to old contour and history file that are known to be correct. For the contour files, only the temperature values at time 2 are tested. For the history files, all temperature values are tested.
Test Directory: FEHM/fehmpytests/ramey
Example File ramey.in
***** Temperature in a Wellbore (Ramey) *****
node
3
-1 -2 -3
0. 0. 0.
0. -1000. 0.
0. -2000. 0.
cont
avs 10000 25.
geom
temperature
end
hist
deg
end
sol
1 -1
init
05.0 0. 20.0 0.03 2500. 20.0 0.03 0.
zone
1
0.105 40. 40. 0.105
0. 0. -2000. -2000.
2
0. .1 .1 0.
0. 0. -2000. -2000.
rock
-1 0 0 2700. 1000. 1.e-10
-2 0 0 2700. 1000. 1.000
cond
-1 0 0 2.7d-00 2.7d-00 2.7d-00
-2 0 0 2.7d-00 2.7d-00 2.7d-00
perm
-1 0 0 1.d-20 1.d-20 1.d-20
-2 0 0 1.d-08 1.d-08 1.d-08
time
0.001 25. 9999 1 1990 2
ctrl
15 1d-6 008
-1 0 0 01
-2 0 0 01
1.0 0.0 1.00
30 1.10 0.000001 1.0
4 0
zone
1
0. .05 .05 0.
0. 0. -10. -10.
2
0. .05 .05 0.
-1990. -1990. -2000. -2000.
flow
-1 0 0 -0.5 -20.00 0.0d00
-2 0 0 00.00 -150.00 1.0d-00
stop